Configuring lun settings, Figure 10-11 – Dell Emulex Family of Adapters User Manual
Page 1620

Boot Version 10.2 for NIC, iSCSI, FCoE, and RoCE Protocols User Manual
P010097-01B Rev. A
10. Configuring and Managing iSCSI Targets with the iSCSISelect Utility
Managing an iSCSI Target
1620
Configuring LUN Settings
A LUN represents an individually addressable logical device that is part of a target. An
initiator negotiates with a target to establish connectivity to a LUN.
To configure a LUN:
1. From the iSCSI Target Configuration screen, press
associated with the iSCSI node.
Figure 10-11 LUN Configuration Menu
2. Press
bootable, you can confirm that you have the boot target configured properly and
see the LUN from which you are booting. By looking at the LUN size, you can also
determine which target is which along with the LUN order.
Note: The LUN order is determined by the target and is in the order listed.
If there are no LUNs available, the following message is displayed:
No LUN available, please check your configuration on the Target.
For more information, see “Troubleshooting for the iSCSI Protocol” on page 1715.
Removing and Logging Out and In of a Configured Target
If you remove or delete a target, you log out of the target and remove it from the list of
targets.
To remove a target, from the iSCSI Target Configuration screen, select the target and
press the
If you log out of a target, you log out of the target but the target is listed in the target list
with the connection status of disconnected. With a logout, you are only deleting the
target session. If you have logged out of a target, you can perform a login.