Dell Emulex Family of Adapters User Manual
Page 928

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
928
1240: Unable to allocate command buffer memory
Could not allocate memory for the command buffer.
Data:
None.
Severity: Error
Log:
LOG_LINK_EVENT
Action:
None required.
1243: Menlo command error. code=%d.\n", mlorsp->code
The Menlo maintenance command failed.
Data:
None.
Severity: Error
Log:
LOG_LINK_EVENT
Action:
None required.
1244: Unable to allocate response buffer memory.
Could not allocate memory for the management command response.
Data:
None.
Severity: Error
Log:
LOG_LINK_EVENT
Action:
None required.
1246: FCoE chip is running golden firmware. Update FCoE chip firmware
immediately
The FCoE is running the golden firmware.
Data:
(1) firmware-type
Severity: Error
Log:
LOG_LINK_EVENT
Action:
Try resetting the FCoE to operational mode and disable maintenance mode.
1247: FCoE chip is running diagnostic firmware. Operational use suspended.
The FCoE is running a diagnostic.
DATA:(1) firmware-type
Severity: Error
Log:
LOG_LINK_EVENT
Action:
Try resetting the FCoE to operational mode.
1248: FCoE chip is running unknown firmware.
The FCoE is running an unknown firmware version.
Data:
(1) firmware-type
Severity: Error
Log:
LOG_LINK_EVENT
Action:
Try resetting the FCoE to operational mode. Try loading latest FCoE firmware.
1249: Invalid FRU data found on adapter. Return adapter to Emulex for repair.
The FRU data on the FCoE chip is invalid.
Data:
(1) firmware-type
Severity: Error
Log:
LOG_LINK_EVENT
Action:
Try resetting the FCoE to operational mode. Try loading latest FCoE firmware or send the
HBA back to Emulex for repair.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)