lpfc_mes0256: Start node timer on NPortId: x%x, timeout value:%d
lpfc_mes0260: Stop node timer on NPortId: x%x, SCSIId: x%x
lpfc_mes0262: Node timeout on NPortId: x%x, SCSIId: x%x
Mailbox Log Messages (0310–0326)
lpfc_mes0310: Mailbox command timeout – HBA unresponsive
Description
Starting timer for disconnected target with NPort
ID and timeout value.
Severity
Information
Log
LOG_ELS verbose
Action
No action needed, informational.
Description
Discontinuing timer for reconnected target with
NPort ID and SCSI ID.
Severity
Information
Log
LOG_ELS verbose
Action
No action needed, informational.
Description
Disconnected NPort ID, SCSI ID has failed to
reconnect within timeout limit.
Severity
Error
Log
LOG_ELS verbose
Action
Review system configuration.
Description
A Mailbox command was posted to the adapter
and did not complete within 30 seconds. sync - 0:
asynchronous mailbox command is issued 1:
synchronous mailbox command is issued.
Severity
Error
Log
LOG_MBOX verbose
Action
This error could indicate a software driver or
firmware issue. If no I/O is going through the
adapter, reboot the system. If these issues persist,
report these errors to Technical Support.