beautypg.com

Dell Emulex Family of Adapters User Manual

Page 1773

background image

Boot Version 10.2 for NIC, iSCSI, FCoE, and RoCE Protocols User Manual

P010097-01B Rev. A

Appendix F. Dell UEFI

Main Configuration Page

1773

CHAP Authentication

Enable the ability of the initiator to use CHAP authentication when
connecting to the iSCSI target.
Available settings include:
• Enabled
• Disabled (default)

CHAP Mutual Authentication

Setting to enable mutual CHAP authentication between the iSCSI
initiator and target.
To use mutual CHAP authentication, specify an initiator secret on
the Initiator Parameters page and configure that secret on the
target.
Available settings include:
• Enabled
• Disabled (default)

IP Version

Control whether IPv4 or IPv6 network addressing is used for the iSCSI
initiator.
Available settings include:
• IPv4
• IPv6
• None (default) – Dual mode

Boot to Target

Control whether the iSCSI initiator boots to the specified iSCSI target
after connection.

Note: This is only applicable to UEFI iSCSI boot.

Available settings include:
• Enabled
• Disabled (default)

HBA Boot Mode

Control whether the iSCSI initiator will boot to the specified iSCSI
target after connection.
Available settings include:
• Enabled (default)
• Disabled

Virtual LAN Mode

Enable or disable iSCSI Virtual LAN mode, which allows a VLAN tag to
be used by iSCSI boot.
Available settings include:
• Enabled
• Disabled (default)

Virtual LAN ID

Specify the ID (tag) to be used for iSCSI VLAN Mode. The valid range
for the VLAN ID is from 0 to 4095.

Table F-7 iSCSI General Parameters Page Menu Options (Continued)

Menu Option