0394: Failed to allocate CQ_EVENT entry
The asynchronous event handler was unable to allocate an event queue entry to which to transfer
the asynchronous event.
Data:
None
Severity: Error
Log:
LOG_MBOX, LOG_SLI
Action:
This could be a V-LINK clear from the switch or a fatal error from the firmware. Perform
a dump from the OneCommand Manager application.
0395: The mboxq allocation failed
The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA
(read link attention) mailbox command.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
None required.
0396:The lpfc_dmabuf allocation failed
The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA
mailbox command.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
None required.
0397:The mbuf allocation failed
The asynchronous link event handler could not allocate DMA-able memory for the READ_LA mailbox
command.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
None required.
0398 Invalid link fault code:
The attempt to read the link attention register has returned an unknown value.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
None required.
0399 Invalid link attention type:
The READ_LA mailbox command has returned an invalid link type.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
None required