700
Viewing the FC/FCoE Event Log
Event Log Interpretation
All events logged by Emulex Storport Miniport are in Event ID 11 with source
“elxfc/elxcna”.
The Storport Miniport driver parameter LogErrors determines what type of
events are logged by the driver; the default setting is “3” which logs only events
of a SEVERE nature; the optional setting of “2” logs events of both SEVERE and
MALFUNCTION type; the optional setting of “1” logs events of SEVERE,
MALFUNCTION and COMMAND type.
Note: For troubleshooting SAN connectivity or device discovery issues, set the
LogErrors to 1.
The Emulex event code is found in byte 0010 and supplementary data is in byte
offsets 0011 through 0013.
Additional Event Log Information
The following tables are not comprehensive but do include those codes, which through
Emulex's experiences in our support and testing environments, we feel are most likely
to show up in SAN environments where issues occur.
ELS/FCP Command Error Status Codes
Internal firmware codes posted by the adapter firmware that explain why a particular
ELS or FCP command failed at the FC level.
CT Command Response Codes
Codes that indicate the response to a FC Common Transport protocol command.
Table A-5 ELS/FCP Command Error Status Codes
Explanation
Code
Remote Stop – Remote port sent an ABTS
0x2
Local Reject – Local Reject error detail
0x3
LS_RJT Received – Remote port sent LS_RJT
0x9
A_RJT Received – Remote port sent BA_RJT
0xA
Table A-6 CT Command Response Codes
Explanation
Code
FC Common Transport Reject
0x8001
FC Common Transport Accept
0x8002