ELS Events (0100 - 0199)

elx_mes0100: FLOGI failure Status:/
TMO:

DESCRIPTION: An ELS FLOGI command that was sent to the fabric failed.
DATA: (1) ulpStatus, (2) ulpWord[4], (3) ulpTimeout
ACTION: This error could indicate a fabric configuration error or internal driver issue.

If this issue persists, report the error to Emulex technical support.

elx_mes0111: Dropping received ELS cmd

DESCRIPTION: The driver decided to drop an ELS Response ring entry.
DATA: (1) ulpStatus, (2) ulpWord[4], (3) ulpTimeout
ACTION: This error could indicate a software driver or firmware issue. If this issue

persists, report the error to Emulex technical support.

elx_mes0113: A FLOGI ELS command was received from DID
in Loop Mode

DESCRIPTION: While in Loop Mode an unknown or unsupported ELS command was

received.
DATA: None
ACTION: Check device DID.

elx_mes0115: Unknown ELS command received from N_Port

DESCRIPTION: Received an unsupported ELS command from a remote N_Port.
DATA: None
ACTION: Check remote N_Port for potential issue.

elx_mes0122 FDISC Failed (value). Fabric Detected Bad WWN

DESCRIPTION: The driver's FDISC failed. The switch reported a bad WWN in the

FLOGI request.
DATA: None
ACTION: Software driver error. If this issue persists, report these errors to Emulex

technical support.

elx_mes0124 Retry illegal cmd retry: delay:

DESCRIPTION: Port rejected ELS command as illegal. Driver retrying.
DATA: None
ACTION: Software driver error. If this issue persists, report these errors to Emulex

technical support.