The Command Reference
1342
Description
The D_Port diagnostic is also known as ClearLink. The D_Port diagnostic is run from
the OneCommand Manager for VMware vCenter CLI by specifying the d_Port
command.
Parameters
Considerations for running DPort
It is not possible to detect if the switch can run D_Port tests before running the
tests. Therefore, a test failure occurs if the D_Port command is run with a switch
that does not support D_Port.
To terminate tests while they are running, type
results are given.
If the overall test result is FAILED, you must re-run the tests successfully or
reset the HBA port to bring the link back up. A message is displayed instructing
you to perform one of these actions if the overall test result is FAILED.
If a test phase fails, the D_Port tests are automatically stopped. In this case,
some of the phases may not be reported in the results. However, the failed
phase will be reported.
More than one error can be reported. In this case, multiple lines are displayed
for the test phase showing each error.
Examples
Successful Test Example
elxvcpcmd.exe v=10.192.203.184 u=root p=password d_port 10:00:00:c9:11:2b:38:b4
Running tests, please wait…
Start time: Wed Oct 2 01:41:35 2013
[After a period of time, the output similar to the following is displayed]
End time: Wed Oct 2 01:45:23 2013
Status: PASSED
Frame Size: 2000
Frame Count: 5000
Roundtrip Link Latency: 1108 nano-seconds
Estimated CableLength: 20 meters
==============================================================
v
The vCenter server IP address.
u
The user name for the vCenter server.
p
The user password for the vCenter server.
WWPN
The WWPN of the FC function of the adapter on which to run tests.