11. Using OneCommand Manager for VMware vCenter Command Line Interface

The Command Reference

1342

Description

The D_Port diagnostic is also known as ClearLink. The D_Port diagnostic is run from

the OneCommand Manager for VMware vCenter CLI by specifying the d_Port

command.

Parameters

Considerations for running DPort

It is not possible to detect if the switch can run D_Port tests before running the

tests. Therefore, a test failure occurs if the D_Port command is run with a switch

that does not support D_Port.

To terminate tests while they are running, type + . In this case not

results are given.

If the overall test result is FAILED, you must re-run the tests successfully or

reset the HBA port to bring the link back up. A message is displayed instructing

you to perform one of these actions if the overall test result is FAILED.

If a test phase fails, the D_Port tests are automatically stopped. In this case,

some of the phases may not be reported in the results. However, the failed

phase will be reported.

More than one error can be reported. In this case, multiple lines are displayed

for the test phase showing each error.

Examples

Successful Test Example

elxvcpcmd.exe v=10.192.203.184 u=root p=password d_port 10:00:00:c9:11:2b:38:b4

Running tests, please wait…

Start time: Wed Oct 2 01:41:35 2013

[After a period of time, the output similar to the following is displayed]

End time: Wed Oct 2 01:45:23 2013

Status: PASSED

Frame Size: 2000

Frame Count: 5000

Roundtrip Link Latency: 1108 nano-seconds

Estimated CableLength: 20 meters

==============================================================

v

The vCenter server IP address.

u

The user name for the vCenter server.

p

The user password for the vCenter server.

WWPN