Dell Emulex Family of Adapters User Manual
Page 316

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
4. CLI Client Command Usage
CIM Interface
316
Add the host IP address with CIM credentials using the AddHost
command. For example:
hbacmd
AddHost
Default CIM Credentials
If you specify the command with the CIM method “m=cim” without specifying the
CIM credentials (userid, password, or namespace), the default value for the missing
CIM credential is obtained in the following order:
1. The information entered using the addhost command is looked up.
2. If no values exist, the information entered using the setcimcred command is
used.
3. If no values exist, the following defaults are used:
username=root
password=root
namespace=root/emulex
portnum=5988
Example of Using the CIM Interface to Display Adapters
In Windows, to display a list of adapters managed for a specified host using the CIM
interface, run the following command:
C:\Program Files\Emulex\Util\OCManager>hbacmd h=10.192.113.128
m=cim u=root p=root n=root/emulex listhbas
The output displayed is similar to the following example:
Manageable HBA List
Port WWN: 10:00:00:00:c9:6b:62:2b
Node WWN: 20:00:00:00:c9:6b:62:2b
Fabric Name: 00:00:00:00:00:00:00:00
Flags: 00000000
Host Name: eng.ma.emulex.com
Mfg: Emulex Corporation
Serial No.: BG73539764
Port Number: n/a
Mode: Initiator
Discovery: cim
Port WWN: 10:00:00:00:c9:6b:62:59
Node WWN: 20:00:00:00:c9:6b:62:59
Fabric Name: 00:00:00:00:00:00:00:00
Flags: 00000000
Host Name: eng.ma.emulex.com