Dcb commands, Getdcbparams – Dell Emulex Family of Adapters User Manual
Page 348

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
DCB Commands
348
If channel management is disabled when this command is executed, an error
message is displayed.
Examples
4 NIC Channels
>>hbacmd CMSetLPVID 00-00-c9-12-34-56 1001 1002 1003 1004
8 Channels, Storage on 2nd channel
>hbacmd CMSetLPVID 00-00-c9-55-43-21 1001 0 1002 1003 1004 1005 1006
1007
DCB Commands
This command shows the DCB and LLDP parameters for iSCSI, FCoE, and NIC adapter
ports.
Notes
DCB commands are for DCB management of OneConnect adapters only.
These commands are not available on OCe11101-EM/EX or OCe11102-EM/EX
adapters. The following error message will be returned:
ERROR: <222>: DCB not available
GetDCBParams
This command shows the active and configured DCB and LLDP settings on a port of a
OneConnect adapter.
Supported By
Linux, Solaris, VMware ESXi, and Windows
Syntax
GetDCBParams
Parameters
Example
hbacmd h=10.192.203.154 GetDCBParams 00-00-c9-93-2f-d8
WWPN
The WWPN of an FC or FCoE port.
MAC
The MAC address of a NIC or iSCSI port.