Diagnostic Commands

354

When using D_Port in a boot from SAN configuration, the configuration must

have redundant paths to the boot LUN and only one of the redundant adapter

ports should be set to D_Port.

Supported By

Linux, VMware ESXi, and Windows

Syntax

DPortTest

Parameters

Considerations When Using D_Port

Because it is not possible to detect if a Brocade switch can support D_Port

functionality, a test failure occurs if the DPortTest command is run with a

switch that does not support D_Port testing.

Typing while the D_Port tests are running terminates the tests and the

completed results are displayed.

If the Overall Test Result is "FAILED", you must either re-run the tests

successfully, or reset the adapter port to bring up the link.

If a test phase fails, the D_Port diagnostics are automatically stopped. As a

result, test phases that would have occurred after the failure are not displayed.

When there is more than one error in a single test phase, multiple lines are

displayed showing each error.

Examples

Successful Test

>hbacmd DPortTest 10:00:00:00:c9:d1:a2:d0

Running D_Port Tests. Please wait. Polling for results.................................

D_Port Test Status: Passed

Buffers Required: 1

Frame Size: 2112

Round Trip Latency: 1898 nanoseconds

Estimated Cable Length: 172 meters

=================================================================================

Test Phase Result Latency Local Errors Remote Errors

=================================================================================

Electrical Loopback Passed 122

Optical Loopback Passed 1898

Reverse Optical Loopback Skipped 0

Link Traffic Passed 0

WWPN

The WWPN of the FC function on the adapter.