5. CLI Client Command Descriptions
Diagnostic Commands
354
When using D_Port in a boot from SAN configuration, the configuration must
have redundant paths to the boot LUN and only one of the redundant adapter
ports should be set to D_Port.
Supported By
Linux, VMware ESXi, and Windows
Syntax
DPortTest
Parameters
Considerations When Using D_Port
Because it is not possible to detect if a Brocade switch can support D_Port
functionality, a test failure occurs if the DPortTest command is run with a
switch that does not support D_Port testing.
Typing
completed results are displayed.
If the Overall Test Result is "FAILED", you must either re-run the tests
successfully, or reset the adapter port to bring up the link.
If a test phase fails, the D_Port diagnostics are automatically stopped. As a
result, test phases that would have occurred after the failure are not displayed.
When there is more than one error in a single test phase, multiple lines are
displayed showing each error.
Examples
Successful Test
>hbacmd DPortTest 10:00:00:00:c9:d1:a2:d0
Running D_Port Tests. Please wait. Polling for results.................................
D_Port Test Status: Passed
Buffers Required: 1
Frame Size: 2112
Round Trip Latency: 1898 nanoseconds
Estimated Cable Length: 172 meters
=================================================================================
Test Phase Result Latency Local Errors Remote Errors
=================================================================================
Electrical Loopback Passed 122
Optical Loopback Passed 1898
Reverse Optical Loopback Skipped 0
Link Traffic Passed 0
WWPN
The WWPN of the FC function on the adapter.