Dell Emulex Family of Adapters User Manual
Page 883

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
883
0143: SLI4 Adapter Hardware Error Data:
The HBA has encountered an unrecoverable error.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
Use hbacmd to retrieve a dump file.
0144: Not a valid WCQE code:
The completion queue handler detected an invalid type.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
None required.
0147: Failed to allocate memory for RSCN event
Memory could not be allocated to send the RSCN event to the management application.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
None required.
0148: Failed to allocate memory for LOGO event
Memory could not be allocated to send the LOGO event to the FC transport.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
None required.
0149: Failed to allocate memory for ELS event
Memory could not be allocated to send the ELS event to the FC transport.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
None required.
0154: Authentication not complete
Authentication was restarted because the previous authentication did not complete.
Data:
None
Severity: Error
Log:
LOG_DISCOVERY
Action:
Check the switch configuration.
0200: CONFIG_LINK bad hba state
A CONFIG_LINK mailbox command completed and the driver was not in the right state.
Data:
None
Severity: Error
Log:
Always
Action:
Software driver error. If this issue persists, report these errors to Technical Support.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)