P010081-01A Rev. A
4. Troubleshooting
Log Messages
889
0268: NS cmd
The NameServer CT request failed.
Data:
None
Severity: Error
Log:
LOG_DISCOVERY
Action:
Check the port and switch configurations.
0271: Illegal State Transition: node
Data:
The current node state does not have a handler for this event.
Data:
(1) nlp_rpi (2) nlp_flag
Severity: Error
Log:
LOG_DISCOVERY
Action:
Verify that all targets are still visible to the SCSI mid-layer.
0272: Illegal State Transition: node
Data:
The driver is completing a PLOGI but do not have the rcv_plogi flag set.
Data:
(1) nlp_rpi (2) nlp_flag
Severity: Error
Log:
LOG_DISCOVERY
Action:
Verify that all targets are still visible to the SCSI mid-layer.
0273: Unexpected discovery timeout, vport State x%x
The discovery process has timed out.
Data:
None
Severity: Error
Log:
LOG_DISCOVERY
Action:
Verify that all targets are still visible.
0274: lpfc_nlp_put: ndlp:x%pusgmap:x%x refcnt:%d, void *)ndlp,
ndlp->nlp_usg_map, atomic_read(&ndlp->kref.refcount)
Data: None
Severity: Warning
Log:
LOG_NODE
Action: None
required.
0275: lpfc_nlp_put: ndlp:x%pusgmap:x%x refcnt:%d, void *)ndlp,
ndlp->nlp_usg_map, atomic_read(&ndlp->kref.refcount)
A kref_put was called again after the node was already inactive.
Data: None
Severity: Warning
Log:
LOG_NODE
Action: None
required.
0276: lpfc_nlp_get: ndlp:x%pusgmap:x%x refcnt:%d, void *)ndlp,
ndlp->nlp_usg_map, atomic_read(&ndlp->kref.refcount)
A kref_get was attempted on a node that was being released.
Data: None
Severity: Warning
Log:
LOG_NODE
Action: None
required.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)