Dell Emulex Family of Adapters User Manual
Page 898

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
898
0350: rc should have been MBX_BUSY
Attempting to unregister a default RPI from an interrupt context and the mailbox state is not busy.
Data:
None
Severity: Error
Log:
LOG_MBOX, LOG_SLI
Action:
None required.
0351: Config MSI mailbox command failed, mbxCmd
The mailbox command sent to the firmware to configure the adapter to use MSI-X has failed.
Data:
None
Severity: Warning
Log:
LOG_MBOX
Action:
Ensure the hardware platform supports MSI-X.
0352: Config MSI mailbox command failed, mbxCmd
The mailbox command sent to the firmware to configure the HBA to use MSI-X has failed.
Data:
None
Severity: Error
Log:
LOG_MBOX
Action:
Ensure the hardware platform supports MSI-X.
0353: Active Mailbox cleared - mailbox timeout exiting
The mailbox timeout handler has determined that the driver is in the process of completing this
mailbox command.
Data:
None
Severity: Error
Log:
LOG_MBOX, LOG_SLI
Action:
None required.
0357: MSI-X interrupt with no EQE
SLI-4 adapter interrupt on the slow path but there is no associated EQE.
Data:
None
Severity: Warning
Log:
LOG_SLI
Action:
None required.
0358: MSI-X interrupt with no EQE
SLI-4 adapter interrupt on the fast path but there is no associated EQE.
Data:
None
Severity: Warning
Log:
LOG_SLI
Action:
None required.
0359:Not a valid slow-path completion " event: majorcode=x%x, minorcode=x%x\n",
bf_get(lpfc_eqe_major_code, eqe), bf_get(lpfc_eqe_minor_code, eqe));
SLI-4: The EQE is invalid.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
None required.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)