Dell Emulex Family of Adapters User Manual
Page 1056

Emulex Drivers Version 10.2 for VMware ESXi User Manual
P010087-01A Rev. A
4. Troubleshooting
Troubleshooting the FC/FCoE Driver
1056
elx_mes0345: Resetting board due to mailbox timeout
DESCRIPTION: A mailbox command failed to complete. The driver is resetting the
port.
DATA: None
ACTION: If the mailbox command fails again, set the lpfc_log_verbose to LOG_MBOX
and retry.
elx_mes0346: Ring
evt_code
DESCRIPTION: The adapter received an asynchronous event that was not a
temperature event.
DATA: None
ACTION: None required.
elx_mes0347: Adapter is very hot, please take corrective action.
Temperature:
DESCRIPTION: Adapter temperature is above normal range
DATA: Temperature in Celsius
ACTION: Shutdown and remove the adapter. Contact customer support.
elx_mes0348: NameServer login: node freed
DESCRIPTION: The enable mode failed to free up the nameserver login.
DATA: None
ACTION: None required.
elx_mes0349: rc should be MBX_SUCCESS
DESCRIPTION: The next mailbox command on the mailbox queue has failed.
DATA: None
ACTION: None required.
elx_mes0350: rc should have been MBX_BUSY
DESCRIPTION: Attempting to unregister a default RPI from an interrupt context and
the mailbox state is not busy.
DATA: None
ACTION: None required.