Changing the plogi retry timer, Figure 6-15 – Dell Emulex Family of Adapters User Manual
Page 1587
Boot Version 10.2 for NIC, iSCSI, FCoE, and RoCE Protocols User Manual
P010097-01B Rev. A
6. Using the FCoE Boot BIOS Utility for x86 and x64 Architectures
Configuring Advanced Adapter Parameters
1587
Changing the PLOGI Retry Timer
This option is especially useful for Tachyon-based RAID arrays. Rarely, a
Tachyon-based RAID array resets itself and the port goes offline temporarily. When the
port returns to operation, the PLOGI retry interval scans the loop to discover this
device. The PLOGI retry interval is the time it takes for one PLOGI to scan the whole
loop. You can choose:
No PLOGI Retry: 0 msec – default
50 msec takes 5 to 6 seconds per device (if 126 AL_PAs are on the loop)
100 msec takes 12 seconds per device (if 126 AL_PAs are on the loop)
200 msec takes 22 seconds per device (if 126 AL_PAs are on the loop)
To set the interval for the PLOGI retry timer:
1. On the main configuration menu (Figure 6-2), select Configure Advanced Adapter
Parameters and press
2. Select Change PLOGI Retry Timer and press
Figure 6-15 is displayed.
Figure 6-15 Change the PLOGI Retry Timer Screen
3. Select the retry timer interval.
4. Press
5. Press
6. For changes to take effect, reboot the system.