4. Troubleshooting
Troubleshooting the FC/FCoE Driver
1046
elx_mes0237: Pending Link Event during Discovery: State
DESCRIPTION:
DATA: None
ACTION: None required.
elx_mes0241: NameServer Rsp Error Data:
DESCRIPTION:
DATA: None
ACTION: None required.
elx_mes0246: RegLogin failed
DESCRIPTION: The firmware returned a failure for the specified RegLogin.
DATA: (1) Did, (2) mbxStatus, (3) hbaState
ACTION: This message indicates that the firmware could not perform a RegLogin for
the specified DID. There may be a limitation on how many nodes an adapter can view.
elx_mes0249: Cannot issue Register Fabric login: Err
DESCRIPTION: Could not issue the fabric reg login; the err value is unique for each
possible failure.
DATA: None
ACTION: None required.
elx_mes0251: NameServer login: no memory
DESCRIPTION: Could not allocate memory for the NDLP structure.
DATA: None
ACTION: None required.
elx_mes0252: Cannot issue NameServer login
DESCRIPTION: Could not issue an ELS PLOGI to the nameserver DID.
DATA: None
ACTION: Check the port connection and switch configuration.
elx_mes0253: Register VPI: Can’t send mbox
DESCRIPTION: Could not issue the REG_LOGIN command for this VPort.
DATA: None
ACTION: None required.