4. Troubleshooting
Log Messages
887
0253: Register VPI: Can’t send mbox\
Could not issue the REG_VPI mailbox command for this VPort.
Data:
None
Severity: Error
Log:
LOG_MBOX
Action:
None required.
0254: Register VPI: no memory” goto mbox_err_exit
Could not allocate memory for the REG_VPI mailbox command.
Data:
None
Severity: Error
Log:
LOG_MBOX
Action:
None required.
0255: Issue FDISC: no IOCB
All of the pre-allocated IOCBs are in use.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
None required.
0256: Issue FDISC: Cannot send IOCB\
Unable to send the fabric IOCB.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
None required.
0257: GID_FT Query error
The GID_FT CT request for the NameServer has failed.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
Check the switch configuration.
0258: Register Fabric login error:
The REG_LOGIN for the fabric has failed.
Data:
None
Severity: Error
Log:
LOG_MBOX
Action:
Check the port connection and the switch configuration.
0259: No NPIV Fabric support
The switch to which the port is connected does not support NPIV.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
Check the switch configuration.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)