beautypg.com

Dell Emulex Family of Adapters User Manual

Page 887

background image

Emulex Drivers Version 10.2 for Linux User Manual

P010081-01A Rev. A

4. Troubleshooting

Log Messages

887

0253: Register VPI: Can’t send mbox\

Could not issue the REG_VPI mailbox command for this VPort.

Data:

None

Severity: Error
Log:

LOG_MBOX

Action:

None required.

0254: Register VPI: no memory” goto mbox_err_exit

Could not allocate memory for the REG_VPI mailbox command.

Data:

None

Severity: Error
Log:

LOG_MBOX

Action:

None required.

0255: Issue FDISC: no IOCB

All of the pre-allocated IOCBs are in use.

Data:

None

Severity: Error
Log:

LOG_ELS

Action:

None required.

0256: Issue FDISC: Cannot send IOCB\

Unable to send the fabric IOCB.

Data:

None

Severity: Error
Log:

LOG_ELS

Action:

None required.

0257: GID_FT Query error

The GID_FT CT request for the NameServer has failed.

Data:

None

Severity: Error
Log:

LOG_ELS

Action:

Check the switch configuration.

0258: Register Fabric login error:

The REG_LOGIN for the fabric has failed.

Data:

None

Severity: Error
Log:

LOG_MBOX

Action:

Check the port connection and the switch configuration.

0259: No NPIV Fabric support

The switch to which the port is connected does not support NPIV.

Data:

None

Severity: Error
Log:

LOG_ELS

Action:

Check the switch configuration.

Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)