Dell Emulex Family of Adapters User Manual
Page 681

Emulex Drivers for Windows User Manual
P010077-01A Rev. A
4. Troubleshooting
Troubleshooting the FC/FCoE Driver
681
lpfc_mes0729: FCP command error: ulpStatus: x%x, ulpWord[4]: x%x, XRI:
x%x, ulpWord[7]: x%x
lpfc_mes0730: FCP response error: Flags: x%x, SCSI status: x%x,
Residual:%d
lpfc_mes0734: Read Check: fcp_parm: x%x, Residual x%x
lpfc_mes0737: SCSI check condition, SenseKey x%x, ASC x%x, ASCQ x%x,
SrbStatus: x%x
Description
The specified device failed an I/O FCP
command.
Severity
Warning
Log
LOG_FCP verbose
Action
Check the state of the target in question.
Remarks
lpfc_mes0730 is also recorded if it is a FCP Rsp
error.
Description
The FCP command failed with a response error.
Severity
Warning
Log
LOG_FCP verbose
Action
Check the state of the target in question.
Remark
lpfc_mes0716, lpfc_mes0734, lpfc_mes0736 or
lpfc_mes0737 is also recorded for more details if
the corresponding SEVERITY level is set.
See Also
lpfc_mes0729
Description
The issued FCP command returned a Read Check
Error.
Severity
Warning
Log
LOG_FCP verbose
Action
Check the state of the target in question.
See Also
lpfc_mes0730
Description
The issued FCP command resulted in a Check
Condition.
Severity
Warning
Log
LOG_FCP verbose
Action
Review SCSI error code values.
See Also
lpfc_mes0730