Dell Emulex Family of Adapters User Manual
Page 426

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
Profile Management Commands
426
RoCE cannot be specified for any multichannel configurations.
This command fails under the following conditions:
Two storage protocols are specified for f1 and f2 and concurrent storage
mode is not available.
Three storage protocols are specified on a port.
The f2 and f3 storage protocols are the same.
For mixed mode, f2 through fm must be NIC or “None”.
For concurrent mode, f3 must be NIC or “None”.
The optional “mctype=” parameter can specify the multichannel type or be set
to "None" to disable multichannel. If the “mctype=” parameter is not specified,
the currently configured multichannel type is not changed.
Note: You must reboot your system after executing this command to run the new
protocols assigned to the channels.
Examples
Mixed Mode - UMC 4 Port, 4 Channels/Port
>hbacmd SetAdapterPortConfig 00-00-c9-12-34-56 p0=nic,iscsi,nic,nic
p1=nic,fcoe,nic,nic p2=nic,fcoe,nic,nic p3=nic,iscsi,nic,nic
mctype=umc
Successfully changed port configuration. A reboot is required to
complete changes.
>hbacmd GetAdapterPortConfig 00-00-c9-12-34-56
Number of Ports : 4
Maximum FCoE Functions : 4
Maximum iSCSI Functions : 4
Mixed Mode I/O Allowed : Yes
Concurrent Mode I/O Allowed : No
ROCE Functions Allowed : Yes
RebootRequired : Yes
Active Configuration
Profile ID : 37
MC Type : UMC
Port Assignments:
Port 0: NIC,NIC,NIC,NIC
Port 1: NIC,NIC,NIC,NIC
Port 2: NIC,NIC,NIC,NIC
Port 3: NIC,NIC,NIC,NIC
Reboot Configuration