lpfc_mes1401: Invalid tag: ContextIndex: x%x, ulpCommand: x%x
NPIV Messages (1800–1899)
lpfc_mes1800: NPIV FDISC failure VPI: x%x Error x%x Reason x%x
lpfc_mes1801: Memory allocation failure for NPIV port: x%x
lpfc_mes1802: Exceeded the MAX NPIV port: x%x
lpfc_mes1803: Virtual Port: x%x VPI:x%x successfully created.
Description
Firmware has generated an invalid response.
Severity
Error
Log
LOG_LINK_EVENT verbose
Action
Review hardware configuration. Contact Emulex
Technical Support.
Description
Virtual Port fails on a FDISC to the switch with
the error and reason listed.
Severity
Error
Log
LOG_NPIV verbose
Action
Check to ensure the switch supports NPIV.
Description
Fails to allocated the block of memory for the
Virtual Port.
Severity
Error
Log
LOG_NPIV verbose
Action
Check to ensure system has sufficient kernel
memory.
Description
Exceeded the number of Virtual Port allows on
the adapter.
Severity
Error
Log
LOG_NPIV verbose
Action
Reduce the number of Virtual Ports.
Description
Virtual Port ID is successfully created.
Severity
Information
Log
LOG_NPIV verbose
Action
No action needed, informational.