8. Managing Adapters and Ports

OCe14000-Series Adapters

222

personality. In this case, after clicking the Apply button, the tab switches to the

single personality view and the selected personality is shown in the personality

pull-down menu.

Configuring RoCE in a Custom View

In Custom view, NIC + RoCE can be configured on the first function of a port. After

checking Configure NIC + RoCE, only the first function of each port is available and

you can select NIC + RoCE or just NIC to run on each port. Storage functions cannot be

configured when any of the ports on the adapter are configured to run NIC + RoCE.

You must also choose a RoCE configuration (i.e. profile) from the list below the port

table.

Choose the RoCE-2 profile for SMB Direct on Windows Server 2012 and

Windows Server 2012 R2 from the pull-down menu in the NIC + RoCE

Configuration box.

Note: Check the Implementer's Lab on the Emulex website for any updated

information on additional use cases for the RoCE-2 profile.

For the RoCE-1 profile, check the Implementer's Lab on the Emulex website for

any updated information on use cases for the RoCE-1 profile.

Note: RoCE configurations are not supported with SR-IOV.

Figure 8-77 Custom NIC + RoCE Configuration