beautypg.com

Dell Emulex Family of Adapters User Manual

Page 888

background image

Emulex Drivers Version 10.2 for Linux User Manual

P010081-01A Rev. A

4. Troubleshooting

Log Messages

888

0260: Register NameServer error:

The REG_LOGIN mailbox command has failed for the NameServer.

Data:

None

Severity: Error
Log:

LOG_ELS

Action:

Check the switch configuration

0261: Cannot register NameServer login:

Either a memory allocation issue or an invalid parameter was sent to the REG_LOGIN.

Data:

None

Severity: Error
Log:

LOG_ELS

Action:

At least one message (0142 0121 0133 0134 0135) should precede this message.

0262: No NPIV Fabric support

The switch to which the port is connected does not support NPIV.

Data:

None

Severity: Error
Log:

LOG_ELS

Action:

Check the switch configuration.

0263: Discovery Mailbox error: state:

Either the driver could not allocate resources or it could not send sparam_mbox or cfglink_mbox.

Data:

(1) address of sparam_mbox command (2) address of cfglink_mbox command

Severity: Error
Log:

LOG_MBOX

Action:

Attempt to unload and reload the driver when it is convenient.

0264: No NPIV Fabric support

The switch to which the port is connected does not support NPIV.

Data:

None

Severity: Error
Log:

LOG_ELS

Action:

Check the switch configuration.

0266: Issue NameServer Req err Data:

The driver was unable to send the NameServer CT command.

Data:

(1) vports fc_flag (2) vports fc_rscn_id_cnt

Severity: Error
Log:

LOG_DISCOVERY

Action:

Check the port and switch configurations.

0267: NameServer GFF Rsp Error ( ) Data:

The NameServer GFF CT request failed.

Data:

(1) vports fc_flag (2) vports fc_rscn_id_cnt

Severity: Error
Log:

LOG_DISCOVERY

Action:

Check the port and switch configurations.

Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)