1094

elx_mes1812: vport_delete failed: Cannot delete physical host

DESCRIPTION: An attempt to delete a port failed because it was to delete a physical

port and not a virtual port. Only VPorts on physical ports can be deleted on an NPIV

system.
DATA: None
ACTION: Software driver error. If this issue persists, report these errors to Emulex

technical support.

elx_mes1813: Create VPORT failed. Cannot get sparam.

DESCRIPTION: The port could not be created because it could not be initialized

possibly due to unavailable resources.
DATA: None
ACTION: Software driver error. If this issue persists, report these errors to Emulex

technical support.

elx_mes1814: Mbox failed, no vport

DESCRIPTION: The VPort field of this mailbox command was not completed.
DATA: None
ACTION: None required.

elx_mes1815 Could not issue unreg_did (default rpis)

DESCRIPTION: Attempt to unregister RPI failed.
DATA: None
ACTION: Software driver error. If this issue persists, report these errors to Emulex

technical support.

elx_mes1818: VPort failed init, mbxCmd READ_SPARM
mbxStatus , rc =

DESCRIPTION: A pending mailbox command issued to initialize port failed.
DATA: (1) mbxCommand, (2) mbxStatus, (3) rc
ACTION: Software driver error. If this issue persists, report these issues to Emulex

technical support.

elx_mes1820: Unable to select SLI-3. Not supported by adapter.

DESCRIPTION: The adapter is not capable of operating in a given mode.
DATA: None
ACTION: This is an informational message. SLI-3 mode is only available on some

adapters. Do not attempt to force an adapter to run in SLI mode 3 if that adapter does

not support SLI-3 mode. Adapters that do not support SLI-3 are configured to run in

SLI-2 mode. Nevertheless, it is recommended to use the auto setting (0).