beautypg.com

Dell Emulex Family of Adapters User Manual

Page 919

background image

Emulex Drivers Version 10.2 for Linux User Manual

P010081-01A Rev. A

4. Troubleshooting

Log Messages

919

0724: I/O flush failure for context <“LUN”,”TGT”,”HOST”,”Unknown”>: cnt

The I/O flush to the LUN, target, or host has failed.

Data:

None

Severity: Error
Log:

LOG_FCP

Action:

None required.

0727: TMF to TGT LUN failed (, )

The task management command failed.

Data:

None

Severity: Error
Log:

LOG_FCP

Action:

None required

0729: FCP cmd failed / status: result:

The specified device failed an FCP command.

Data:

(1) ulpContext (2) iotag

Severity: Warning
Log:

LOG_FCP verbose

Action:

Check the state of the target in question.

0730: FCP command failed: RSP

The FCP command failed with a response error.

Data:

(1) resp_info (2) scsi_status (3) ResId (4) SnsLen (5) RspLen (6)rspInfo3

Severity: Warning
Log:

LOG_FCP verbose

Action:

Check the state of the target in question.

0734: FCP read check error

The issued FCP command returned a read check error.

Data:

(1) fcpDl (2) rspResId (3) fcpi_parm (4) cmd[0]

Severity: Warning
Log:

LOG_FCP verbose

Action:

Check the state of the target in question.

0735: FCP Read Check Error and Underrun Data

HBA reported under run from storage array.

Data:

(1) vpi (2) fcpDI (3) res_id (4) fcpi_parm

Severity: Warning
Log:

LOG_FCP_ERROR verbose

Action:

No action needed, informational.

0748: Abort handler timed out waiting for abort to complete:ret D

LUN

The abort handler timed out waiting for abort to complete.

Data:

None

Severity: Error
Log:

Always

Action:

None required.

Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)