Dell Emulex Family of Adapters User Manual
Page 919

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
919
0724: I/O flush failure for context <“LUN”,”TGT”,”HOST”,”Unknown”>: cnt
The I/O flush to the LUN, target, or host has failed.
Data:
None
Severity: Error
Log:
LOG_FCP
Action:
None required.
0727: TMF
The task management command failed.
Data:
None
Severity: Error
Log:
LOG_FCP
Action:
None required
0729: FCP cmd
The specified device failed an FCP command.
Data:
(1) ulpContext (2) iotag
Severity: Warning
Log:
LOG_FCP verbose
Action:
Check the state of the target in question.
0730: FCP command failed: RSP
The FCP command failed with a response error.
Data:
(1) resp_info (2) scsi_status (3) ResId (4) SnsLen (5) RspLen (6)rspInfo3
Severity: Warning
Log:
LOG_FCP verbose
Action:
Check the state of the target in question.
0734: FCP read check error
The issued FCP command returned a read check error.
Data:
(1) fcpDl (2) rspResId (3) fcpi_parm (4) cmd[0]
Severity: Warning
Log:
LOG_FCP verbose
Action:
Check the state of the target in question.
0735: FCP Read Check Error and Underrun Data
HBA reported under run from storage array.
Data:
(1) vpi (2) fcpDI (3) res_id (4) fcpi_parm
Severity: Warning
Log:
LOG_FCP_ERROR verbose
Action:
No action needed, informational.
0748: Abort handler timed out waiting for abort to complete:ret
The abort handler timed out waiting for abort to complete.
Data:
None
Severity: Error
Log:
Always
Action:
None required.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)