Dell Emulex Family of Adapters User Manual
Page 719

Emulex Drivers for Windows User Manual
P010077-01A Rev. A
Appendix A. Error and Event Log Information
iSCSI Error and Event Log
719
0x34
Warning
Connection was invalidated
internally due to a bad opcode
in the PDU header.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.
0x35
Warning
Connection was invalidated
internally due to a received
ITT/TTT that did not belong to
this connection.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.
0x36
Warning
Connection was invalidated
internally; the received
ITT/TTT value was greater
than the maximum supported
ITTs/TTTs.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.
0x37
Warning
Connection was invalidated
internally due to an incoming
TCP RST.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.
0x38
Warning
Connection was invalidated
internally due to TCP protocol
warning (SYN received,
maximum retransmits
exceeded, urgent received,
etc.).
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.
0x39
Warning
Connection was invalidated
internally due to TCP RST sent
by the transmit side.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.
0x3a
Warning
Connection was invalidated
internally due to an incoming
TCP FIN.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.
0x3b
Warning
Connection was invalidated
internally due to a bad
unsolicited PDU (unsolicited
PDUs are PDUs with
ITT=0xffffffff).
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.
0x3c
Warning
Connection was invalidated
internally due to a bad WRB
index.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.
0x3d
Warning
Command was invalidated
internally; the received
command had residual
overrun bytes.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.
0x3e
Warning
Command was invalidated
internally; the received
command had residual
underrun bytes.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.
Table A-15 iSCSI Error Log Entries on Windows 7, Windows 8, Windows 8.1, Windows Server 2008 R2, Windows
Server 2012, and Windows Server 2012 R2 (Continued)
Message ID
Severity
Message
Recommended Resolution