Emulex Drivers for Windows User Manual

P010077-01A Rev. A

Appendix A. Error and Event Log Information

iSCSI Error and Event Log

719

0x34

Warning

Connection was invalidated
internally due to a bad opcode
in the PDU header.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.

0x35

Warning

Connection was invalidated
internally due to a received
ITT/TTT that did not belong to
this connection.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.

0x36

Warning

Connection was invalidated
internally; the received
ITT/TTT value was greater
than the maximum supported
ITTs/TTTs.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.

0x37

Warning

Connection was invalidated
internally due to an incoming
TCP RST.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.

0x38

Warning

Connection was invalidated
internally due to TCP protocol
warning (SYN received,
maximum retransmits
exceeded, urgent received,
etc.).

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.

0x39

Warning

Connection was invalidated
internally due to TCP RST sent
by the transmit side.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.

0x3a

Warning

Connection was invalidated
internally due to an incoming
TCP FIN.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check the iSCSI configuration.

0x3b

Warning

Connection was invalidated
internally due to a bad
unsolicited PDU (unsolicited
PDUs are PDUs with
ITT=0xffffffff).

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.

0x3c

Warning

Connection was invalidated
internally due to a bad WRB
index.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.

0x3d

Warning

Command was invalidated
internally; the received
command had residual
overrun bytes.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.

0x3e

Warning

Command was invalidated
internally; the received
command had residual
underrun bytes.

This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.

Table A-15 iSCSI Error Log Entries on Windows 7, Windows 8, Windows 8.1, Windows Server 2008 R2, Windows
Server 2012, and Windows Server 2012 R2 (Continued)

Message ID

Severity

Message

Recommended Resolution