Discovering vnics using the emulex cim provider, To determine vnics using the ucna cim provider, Discovering vnics using the emulex cim provider 5 – Dell Emulex Family of Adapters User Manual
Page 1155

CIM Provider Package Installation Guide
P010091-01A Rev. A
3. Using the Adapter
Discovering vNICs Using the Emulex CIM Provider
1155
Executing a Diagnostic Test with an Emulex FC Adapter
To execute a diagnostic test with an FC adapter:
1. Get the instance of the managed element (ELXHBA_PortController). For example:
wbemcli -noverify ein
‘https://root:
-nl
2. Get the instance of the ELXHBA_FCHBADiagnostictest class. For example:
wbemcli -noverify ein
‘https://root:
-nl
3. Invoke the method RunDiagnosticservice on the ELXHBA_FCHBADiagnostictest.
For example:
wbemcli -noverify cm
‘https://root: instance from step 2>’ RunDiagnosticservice.ManagedElement= from step 1>’ 4. A CIM_ConcreteJob instance is created for each diagnostic test run. For example: wbemcli -noverify ein ‘https://root: -nl 5. Results of the diagnostic test runs are available in ELXHBA_DiagnosticCompletionRecord class instances. For example: wbemcli -noverify ein ‘https://root: etionrecord’ -nl 6. The diagnostic logs can be cleared using the ClearLog function of ELXHBA_DiagnosticsLog class. For example: wbemcli -noverify cm ‘https://root: Diagnostic log instance>’ ClearLog Discovering vNICs Using the Emulex CIM Provider To Determine vNICs Using the UCNA CIM Provider 1. Find all the CIM_VLANEndpoint instances whose SystemName property has a value equal to the name of the desired host. These instances are vNIC endpoints. 2. Find the CIM_EndpointIdentity instance associating the CIM_VLANEndpoint instance to a CIM_LANEndpoint instance. Follow the association to the CIM_LANEndpoint. 3. Find the instance of CIM_DeviceSAPImplementation instance that associates the CIM_LANEndpoint to an instance of CIM_EthernetPort. Follow the associations to the CIM_EthernetPort instance representing the vNIC.