beautypg.com

Dell Emulex Family of Adapters User Manual

Page 434

background image

OneCommand Manager Command Line Interface Version 10.2 User Manual

P010067-01A Rev. A

5. CLI Client Command Descriptions

Profile Management Commands

434

NParEP Mode : Disabled

Port Assignments:

Port 1 (p0): NIC,iSCSI,NIC,FCoE

Port 2 (p1): NIC,FCoE,iSCSI,NIC

Note: (pN) labels are the port parameter names to use in the

SetAdapterPortConfig command (e.g. p0=NIC,FCoE p1=NIC,iSCSI).

4 Ports - NParEPMode-Enabled, 4 Functions/Port

>hbacmd setadapterportconfig 00-00-c9-12-34-56 p0=nic,iscsi,fcoe,nic

p1=nic,iscsi,none,nic p2=nic,iscsi,nic,fcoe p3=nic,nic,iscsi,none

mctype=npar nparepmode=1

Successfully changed port configuration. A reboot is required to

complete changes.

>hbacmd getadapterportconfig 00-00-c9-12-34-56

Number of Ports : 4

Maximum FCoE Functions : 4

Maximum iSCSI Functions : 4

Mixed Mode I/O Allowed : Yes

Concurrent Mode I/O Allowed : Yes

ROCE Functions Allowed : Yes

RebootRequired : Yes

Active Configuration

Profile ID : 33

MC Type : NPAR

Port Assignments:

Port 1: NIC,NIC,NIC,NIC

Port 2: NIC,NIC,NIC,NIC

Port 3: NIC,iSCSI,NIC,FCoE

Port 4: NIC,iSCSI,FCoE,None

Reboot Configuration

Profile ID : 33

MC Type : NPAR

NParEP Mode : Enabled

Port Assignments:

Port 1 (p0): NIC,iSCSI,FCoE,NIC

Port 2 (p1): NIC,iSCSI,None,NIC

Port 3 (p2): NIC,iSCSI,NIC,FCoE

Port 4 (p3): NIC,NIC,iSCSI,None