Dell Emulex Family of Adapters User Manual
Page 434

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
Profile Management Commands
434
NParEP Mode : Disabled
Port Assignments:
Port 1 (p0): NIC,iSCSI,NIC,FCoE
Port 2 (p1): NIC,FCoE,iSCSI,NIC
Note: (pN) labels are the port parameter names to use in the
SetAdapterPortConfig command (e.g. p0=NIC,FCoE p1=NIC,iSCSI).
4 Ports - NParEPMode-Enabled, 4 Functions/Port
>hbacmd setadapterportconfig 00-00-c9-12-34-56 p0=nic,iscsi,fcoe,nic
p1=nic,iscsi,none,nic p2=nic,iscsi,nic,fcoe p3=nic,nic,iscsi,none
mctype=npar nparepmode=1
Successfully changed port configuration. A reboot is required to
complete changes.
>hbacmd getadapterportconfig 00-00-c9-12-34-56
Number of Ports : 4
Maximum FCoE Functions : 4
Maximum iSCSI Functions : 4
Mixed Mode I/O Allowed : Yes
Concurrent Mode I/O Allowed : Yes
ROCE Functions Allowed : Yes
RebootRequired : Yes
Active Configuration
Profile ID : 33
MC Type : NPAR
Port Assignments:
Port 1: NIC,NIC,NIC,NIC
Port 2: NIC,NIC,NIC,NIC
Port 3: NIC,iSCSI,NIC,FCoE
Port 4: NIC,iSCSI,FCoE,None
Reboot Configuration
Profile ID : 33
MC Type : NPAR
NParEP Mode : Enabled
Port Assignments:
Port 1 (p0): NIC,iSCSI,FCoE,NIC
Port 2 (p1): NIC,iSCSI,None,NIC
Port 3 (p2): NIC,iSCSI,NIC,FCoE
Port 4 (p3): NIC,NIC,iSCSI,None