Page 970: Compression, E simulator configuration register, E maximum compression, E maximum
RMC70/150 and RMCTools User Manual
If the Positive and Negative Physical Limits are both zero, the spring force is not
simulated and this parameter is not used.
Changing this Parameter
For best results, always change this parameter only from Axis Tools. If the axis is in
Simulate mode, and this parameter is changed, simulate model will be suspended until
the last simulate mode parameter register (Max Compression [Fx:127]) has been
updated. At this point, the new simulator model will be calculated and the simulator
model will be activated. When the simulator model is suspended, the Actual Position will
not move.
Certain simulator settings may result in an invalid model. If this occurs, change your
settings. See the Simulating Motion topic for more details.
9.2.2.3.11. Maximum Compression (Simulator)
Type: Axis Parameter Register
RMC70 Address: %MDn.127, where n = 12 + the axis number
RMC150 Address: %MDn.127, where n = 24 + the axis number
System Tag: _Axis[n].SimMaxComp, where n is the axis number
How to Find: Axes Parameters Pane, All tab: Simulate
Data Type: REAL
Units: pu
Range: >0
Default Value: 0.01
Description
At the Positive and Negative Physical Limits, the simulator simulates a spring force that
extends outside the limit by the distance specified by the Maximum Compression
parameter. The Maximum Force specifies the max force at the max compression. The
spring force increases linearly from zero at the limit to the max force at the max
compression. This is useful for simulating pressure or force control.
If the Positive and Negative Physical Limits are both zero, the spring force is not
simulated and this parameter is not used.
Changing this Parameter
For best results, always change this parameter only from Axis Tools. If the axis is in
Simulate mode, and this parameter is changed, simulate model will be suspended until
the last simulate mode parameter register (Max Compression [Fx:127]) has been
updated. At this point, the new simulator model will be calculated and the simulator
model will be activated. When the simulator model is suspended, the Actual Position will
not move.
Certain simulator settings may result in an invalid model. If this occurs, change your
settings. See the Simulating Motion topic for more details.
9.2.2.3.12. Simulator Configuration Register
Type: Axis Parameter Register
RMC70 Address: %MDn.116, where n = 12 + the axis number
950
Delta Computer Systems, Inc.