Using mitsubishi plcs with the rmc, Mitsubishi q-series, Schneider electric plcs via modbus – Delta RMC151 User Manual
Page 583: Mitsubishi q-series plcs with the rmc
6 Communication
Delta provides instrument drivers for use with National Instruments LabVIEW™ software.
These instrument drivers include full-fledged examples that are ready to run.
Installing the Instrument Drivers
Delta recommends installing the instrument drivers directly from the LabVIEW™
software:
1. In LabVIEW, on the Tools menu, choose Instrumentation and click Find
Instrument Drivers.
2. Choose Delta Computer Systems and click Search.
3. Choose the driver for your RMC and your RMC LabVIEW version, and click Install.
Wait for the installation to complete.
After completing the installation, the RMC instrument drivers will be available on the
Instrument Driver pallete. You can fin examples by searching for "RMC" in the LabVIEW
Example Finder.
6.11.6. Using Mitsubishi PLCs with the RMC
Q-Series
The RMC can communicate with the Mitsubishi Q-series PLC in the following ways:
•
Ethernet (RMC75E or RMC150E): Using the QJ71E71-100 module.
Using the Procedure Exist control method. See the Mitsubishi Procedure Exist topic for
details. A sample PLC project is available on the downloads page of Delta's website.
•
Ethernet (RMC75E or RMC150E): Using the QJ71MT91 module.
Using the Modbus/TCP protocol. A sample PLC project is available on the downloads
page of Delta's website. The download includes a document explaining how to set up
and use the QJ71MT91.
•
Serial RS-232/485 (RMC75S): Using the QJ71C24N module.
Using the Bidirectional protocol. See the Mitsubishi Bidirectional Protocol topic for
details. A sample PLC project is available on the downloads page of Delta's website.
FX3U
The RMC can communicate with the Mitsubishi FX3U PLC in the following ways:
•
Ethernet (RMC75E or RMC150E):
Using the Procedure Exist control method. See the Mitsubishi Procedure Exist topic for
details.
6.11.7. Using Schneider Electric (Modicon) PLCs via
Modbus/TCP
The RMC75E and RMC150E can communicate with any Schneider Electric Modicon PLCs that
support Modbus/TCP (Ethernet) or Modbus RTU (serial RS-232). The RMC75E and RMC150E
cannot communicate via Modbus Plus.
The RMC75E and RMC150E can also communicate with Schneider Electric Modicon PLCs via
deltamotion.com
563