background image

RMC70/150 and RMCTools User Manual

then use

Axis Owner

12-

23

Reserved

F32:6

16397

D16396 REAL

%MD32.6

-

-

Reserved

F32:7

16399

D16398 REAL

%MD32.7

-

-

Reserved

F32:8

16401

D16400 REAL

%MD32.8 REAL

Read Only Plot ID

F32:9

16403

D16402 REAL

%MD32.9 REAL

Read Only Plot State

0 = not triggered, 1

= capturing, 2 =

complete

F32:10

16405

D16404 REAL

%MD32.10 DINT

Read Only Plot Captured

Samples
Number of plot

samples captured.

Only applies for Plot

State > 0.

F32:11

16407

D16406 REAL

%MD32.11 DINT

Read Only Plot Sample 0 Time

Time that first plot

sample was

captured. In control

loops since

controller startup

(low 24 bits). Only

applies for Plot

State > 0.

F32:12

16409

D16408 REAL

%MD32.12 DINT

Read Only Plot Trigger Time

Time that plot

trigger occurred. In

control loops since

controller startup

(low 24 bits). Only

applies for Plot

State > 0.

F32:13

16411

D16410 REAL

%MD32.13 DINT

Read Only Plot Trigger Index

Index of the plot

sample at which the

plot trigger

occurred. Only

applies for Plot

State > 0.

F32:14-

15

16413-

16415

D16412-
D16414

-

%MD32.14-

15

-

-

Reserved

F32:16-

31

16417-

16447

D16416-
D16446

REAL

%MD32.16-

31

DWORD Read/Write Plot Data Sets 0-15

Addresses
Files %MDn:16-31

contain the

Addresses for plot

Data Sets 0-15.
Bits 0-11 Element

1072

Delta Computer Systems, Inc.

This manual is related to the following products: