beautypg.com

Command: direct output halt (3), Direct output halt (3), E direct output halt (3) – Delta RMC151 User Manual

Page 720: S a direct output halt (3)

background image

RMC70/150 and RMCTools User Manual

Supported Axes: All

Supported Control Modes: All

Firmware Requirement: 1.00 or newer


See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

None.

Description

This command initiates an Open Loop Halt. See the Open Loop Halt topic for details.

Target Generator State Bits

The Target Generator bits in the Status Bits register indicate which portion of the move

the axis is currently in. These bits are useful when programming complex motion

sequences.
Target Generator Done bit
This bit indicates the move is complete, which occurs when the Control Output has

reached zero.
Target Generator State A and B bits

B

A Description

0

0

Done

0

1

Reserved

1

0

Reserved

1

1

Ramping Control Output toward 0 volts

8.4.2.6. Command: Direct Output Halt (3)

Supported Axes: All

Supported Control Modes: All

Firmware Requirement: 1.00 or newer


See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

None.

Description

This command initiates a Direct Output Halt. See the Direct Output Halt topic for details.

Target Generator State Bits

The Target Generator bits in the Status Bits register indicate which portion of the move

the axis is currently in. These bits are useful when programming complex motion

sequences.
Target Generator Done bit

700

Delta Computer Systems, Inc.

This manual is related to the following products: