beautypg.com

Halt group number, Halt group number 0, E halt group number – Delta RMC151 User Manual

Page 1020: Halt group, E halt group, Number

background image

RMC70/150 and RMCTools User Manual

AutoStopCfg1.OutSat

bits 6-8

Output

Saturated

AutoStopCfg1.FaultIn

bits 9-11 Fault Input

AutoStopCfg1.PosLimitIn

bits 12-14 Positive Limit

Input

AutoStopCfg1.NegLimitIn

bits 15-17 Negative

Limit Input

AutoStopCfg1.NoTrans

bits 18-20 No

Transducer

AutoStopCfg1.TransOverflow

bits 21-23 Transducer

Overflow

%MD12.107 DWORD AutoStopCfg2.NoiseErr

bits 0-2

Noise Error

AutoStopCfg2.PosOvertravel

bits 3-5

Positive

Overtravel

AutoStopCfg2.NegOvertravel

bits 6-8

Negative

Overtravel

AutoStopCfg2.CmdErr

bits 9-11 Command

Error

AutoStopCfg2.CmdMod

bits 12-14 Command

Modified

AutoStopCfg2.CfgErr

bits 15-17 Configuration

Error

AutoStopCfg2.RunErr

bits 18-20 Runtime

Error

%MD12.108 DWORD AutoStopCfg3.PFNoTrans

bits 6-8 No Transducer

(Pressure/Force)

AutoStopCfg3.PFTransOverflow bits 9-

11

Transducer

Overflow

((Pressure/Force)

AutoStopCfg3.PFNoiseErr

bits 12-

14

Noise Error

(Pressure/Force)

AutoStopCfg3.PFFollowErr

bits 15-

17

Following Error

(Pressure/Force)

9.2.2.8.2. Halt Group Number

Type: Axis Parameter Register

RMC70 Address: %MDn.112, where n = 12 + the axis number

RMC150 Address: %MDn.112, where n = 24 + the axis number

System Tag: _Axis[n].HaltGrpNo, where n is the axis number

How to Find: Axes Parameters Pane, All tab: Halt Group Number

Data Type: DINT

Units: none

Range: RMC70: 0 (none), 1 to 2, whole numbers only

RMC150: 0 (none), 1 to 8, whole numbers only

Default Value: 0

1000

Delta Computer Systems, Inc.

This manual is related to the following products: