beautypg.com

Delta RMC151 User Manual

Page 651

background image

7 Hardware

Overvoltage protection Outputs are protected by clamp diodes

Fault Input

Input Characteristics 12-24 VDC, sinking or sourcing

Logic Polarity True High

Input "High" Range 7 to 26.4 VDC (polarity independent)

3 mA maximum

Input "Low" Range 0 to 3.5VDC (polarity independent)

<1mA

Maximum Propagation

Delay

100µs

Enable Output

Output Type Solid State Relay

Logic Polarity User Selectable to Active Open or Active Closed

Isolation 500 VAC

Rated Voltage 12-24 V, max 30 V (DC or peak AC voltage)

Maximum Current 75 mA

Maximum Propagation

Delay

1.5 ms

Closed Low Impedance (50 Ω maximum)

Open High Impedance (<1 µA leakage current at 250 V)

See the Fault Input and Enable Output topics for usage details.

LEDs

Axis LED

This LED represents the input and control status for the axis. This bi-color (red/green)

LED has the following states:

State

Description

Steady

Off

No power or this input is not assigned to an axis.

Steady

Green

The axis is either in closed loop control or is a reference axis. The axis is

not halted.

Flashing

Green

The input is in open loop and the axis is not halted (not possible for

reference axes).

Flashing

Red

A Closed Loop Halt or External Halt has occurred because an error bit is set

(not possible for reference axes). The LED will not turn red due to a halt

caused by halt command.

Steady

Red

An Open Loop Halt or Direct Output Halt has occurred because an error bit

is set (for reference axes, any halt has occurred). The LED will not turn red

due to a halt caused by halt command.

En/F LED

This LED represents the status of the Enable Output and Fault Input for the axis. This bi-

color (red/green) LED will have the following states:

State

Description

Steady

Off

No power or the Control Output is not assigned to an axis.

Steady

The Fault input is inactive, and the Enable output is active.

deltamotion.com

631

This manual is related to the following products: