The part number of the Resolver module is Rn, where n is the number of Resolver
modules.
For example, RMC150E-R1 is an RMC150E with one Resolver module. RMC150E-R3-Q1 is
an RMC150E with three Resolver modules and one Quadrature module.
Setting Up the Resolver Module
1. Wire the resolver according to the RMC150 Resolver Wiring topic.
2. Set the following parameters:
•
•
•
3. Scale the axis. Typically, resolvers will use Rotary Scaling. Notice that one revolution
of the resolver will always consist of 65,536 counts on the RMC, regardless of the
resolver resolution parameter.
Specifications
For general specifications on the RMC150, see the RMC150 Overview topic.
Resolver Interface
Axes Two per module
Reference Frequency 800 Hz to 5 kHz
Reference Output
Voltage
1.42 to 4.8V RMS
Reference Output
Current
28 mA max
Resolver Transformation
Ratio
(SIN
MAX
/Reference)
0.42 to 1.41
Resolver Input Voltage 2V RMS ±15%
Resolution 14 or 16 bits
Maximum Speed 14 bits: 3000 RPM
16 bits: 600 RPM
Maximum Acceleration 14 bits: 1200 RPS per second
16 bits: 60 RPS per second
Accuracy 4 Minutes + 1 LSB
Control Outputs
Range ±10 V @ 5 mA (2 kΩ or greater load)
(For current output, use the VC2124 accessory:±10 mA to
±200 mA in 10mA steps)
Tolerance At 10 V: +200 mV, -100 mV
At 0 V: ±50 mV
At -10 V: +100 mV, -200 mV
Resolution 14 bits
Output Isolation 500VAC