8.4.4.3. Command: Sync Stop (17)

Supported Axes: Position Control Axes

Supported Control Modes: Position PID, Position I-PD

Firmware Requirement: 3.00 or newer


See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Deceleration Rate (pos-units/s

2

)

>0

Description

This command stops all synchronized axes in this axis's sync group. All axes remain

synchronized together throughout the stop.
For the synchronized axes to which this command is issued, the current velocities and

positions of those axes will be used to determine the deceleration rates such that none of

those axes exceed the requested Deceleration Rate. Any other axes in the same group

to which the Sync Stop (17) command was not issued will be ratioed according to their

current ratios.
If this command is issued to an axis that is not synchronized, a command error will occur.
For more details on synchronizing axes, refer to the Sync Move Absolute (13) command.

Status Bits

In Position Bit
The Sync Stop (17) command will not turn on this bit.
Target Generator Bits
The Target Generator bits in the Status Bits register indicate which portion of the move

the axis is currently in. These bits are useful when programming complex motion

sequences.
Target Generator Done bit
This bit indicates the move is complete, which occurs when the Target Position has

stopped.
Target Generator State A and B bits

B

A Description

0

0

Done

0

1

Reserved

1

0

Reserved

1

1

Decelerating to zero velocity

710