Rmc150, Rmc150 mounting instructions, Rmc150 5 – Delta RMC151 User Manual
Page 1165: Rmc150 mounting instructions 5
10 Wiring and Installation
Daisy-Chaining Quadrature Inputs
One quadrature encoder can typically output its A and B signals to thirty-two (32) RMC70
Q1 modules. Use a daisy-chain topology as shown below. Do not use a star topology. Add
termination only to the last input, as illustrated. Incorrect termination will result in
distorted signals and will cause incorrect transducer readings.
10.3. RMC150
10.3.1. RMC150 Mounting Instructions
Mounting Options:
• Symmetrical DIN 3
• Panel-mount
Orientation:
The RMC should be mounted upright on a vertical surface, such that the air holes are on
top and bottom.
Clearance above and below:
The amount of clearance required depends on the maximum ambient temperature:
Ambient Temperature
Clearance
122 - 140°F (50-60°C)
3 in (7.6 cm)
86 to 122°F (30 to 50°C)
2 in (5.1 cm)
Less than 86°F (30°C)
1 in (2.5 cm)
Mounting Dimensions
The width depends on the number of slots in the backplane.
Width
3 Slots 4.10 in.
4 Slots 5.10 in.
5 Slots 6.10 in.
6 Slots 7.10 in.