beautypg.com

Delta RMC151 User Manual

Page 677

background image

7 Hardware

For example, RMC150E-M1 is an RMC150E with one MDT module. RMC150E-M3-Q1 is an

RMC150E with three MDT modules and one Quadrature module.

Supported Transducers

The following tables summarize the major transducer options supported by the MDT

module:

MDT Options

Value

Types

Start/Stop (S/S)
Pulse-Width-Modulated

(PWM)

Count Range

32 bits

Wiring

Differential, 5 V, RS-422,
Single-ended 5 V

Interrogation

Modes

External. Notice that internal

interrogation is not

supported.

MDT Count

Rate

120 MHz

Blanking Period
The RMC150 has a blanking period options of 5 µsec (default) and 21 µsec. Some older

transducers, such as Temposonics I and II with neuter outputs, require the longer

blanking period. For more details, see the MDT Fundamentals and MDT Blanking Period

topics.

Setting Up the MDT Module

To set up the MDT module, read the following topics:
MDT Wiring
MDT Scaling

Specifications

For general specifications on the RMC150, see the RMC150 Overview topic.

MDT Interface

Axes Two per module

Inputs Two RS-422 differential (can also be used single-ended)

Outputs Two RS-422 differential (can also be used single-ended)

ESD Protection 15 kV

Resolution 0.001 (25.4 µm) in Start/Stop; 0.0001 in (2.54 µm) PWM

Count Rate 120 MHz

Control Outputs

Range ±10 V @ 5 mA (2 kΩ or greater load)

(For current output, use the VC2124 accessory:±10 mA to

±200 mA in 10 mA steps)

Tolerance At 10 V: +200mV, -100 mV

At 0 V: ±50mV

At -10 V: +100 mV, -200 mV

Resolution 12 bits

Output Isolation 500 VAC

Overload Protection One-second short-circuit duration

deltamotion.com

657

This manual is related to the following products: