beautypg.com

Indirect data map definition, Indirect data map – Delta RMC151 User Manual

Page 1077

background image

9 Register Reference

command area is still available for backwards compatibility with earlier versions of RMC70s

that did not support the new larger command area (9 command parameters per command).

The file 16 registers should not be used to issue commands that require more than 5

command parameters.

AB
DF1,
CSP

Address

Modbus

TCP,RTU

Address

FINS
Address

External
Data

Type

Internal
IEC

Address

Internal

Data

Type

Register Name

Axis 0 Command
F16:0

8193

D8192 REAL

%MD16.0

REAL

Axis 0 Command

F16:1

8195

D8194 REAL

%MD16.1

REAL

Axis 0 Command Parameter 1

F16:2

8197

D8196 REAL

%MD16.2

REAL

Axis 0 Command Parameter 2

F16:3

8199

D8198 REAL

%MD16.3

REAL

Axis 0 Command Parameter 3

F16:4

8201

D8200 REAL

%MD16.4

REAL

Axis 0 Command Parameter 4

F16:5

8203

D8202 REAL

%MD16.5

REAL

Axis 0 Command Parameter 5

Axis 1 Command
F16:6

8205

D8204 REAL

%MD16.6

REAL

Axis 1 Command

F16:7

8207

D8206 REAL

%MD16.7

REAL

Axis 1 Command Parameter 1

F16:8

8209

D8208 REAL

%MD16.8

REAL

Axis 1 Command Parameter 2

F16:9

8211

D8210 REAL

%MD16.9

REAL

Axis 1 Command Parameter 3

F16:10 8213

D8212 REAL

%MD16.10 REAL

Axis 1 Command Parameter 4

F16:11 8215

D8214 REAL

%MD16.11 REAL

Axis 1 Command Parameter 5

Axis 2 Command
F16:12 8217

D8216 REAL

%MD16.12 REAL

Axis 2 Command

F16:13 8219

D8218 REAL

%MD16.13 REAL

Axis 2 Command Parameter 1

F16:14 8221

D8220 REAL

%MD16.14 REAL

Axis 2 Command Parameter 2

F16:15 8223

D8222 REAL

%MD16.15 REAL

Axis 2 Command Parameter 3

F16:16 8225

D8224 REAL

%MD16.16 REAL

Axis 2 Command Parameter 4

F16:17 8227

D8226 REAL

%MD16.17 REAL

Axis 2 Command Parameter 5

Axis 3 Command
F16:18 8229

D8228 REAL

%MD16.18 REAL

Axis 3 Command

F16:19 8231

D8230 REAL

%MD16.19 REAL

Axis 3 Command Parameter 1

F16:20 8233

D8232 REAL

%MD16.20 REAL

Axis 3 Command Parameter 2

F16:21 8235

D8234 REAL

%MD16.21 REAL

Axis 3 Command Parameter 3

F16:22 8237

D8236 REAL

%MD16.22 REAL

Axis 3 Command Parameter 4

F16:23 8239

D8238 REAL

%MD16.23 REAL

Axis 3 Command Parameter 5

RMC70 Registers, Files 17-18: Indirect Data Map Registers

Use the Indirect Data Map Editor to edit the Indirect Data Map.
The Indirect Data Map registers (%MD18.0 - %MD18.31) are the registers that should be

accessed at runtime by a PLC when reading or writing the Indirect Data. The Indirect Data

Map Definition (registers %MD17.0 - %MD17.31) contains the addresses of the referenced

registers, not the data. Reading or writing to these registers will not access the Indirect Data

via a PLC.

deltamotion.com

1057