9 Register Reference

Only

F26:9

13331

D13330 REAL

%MD26.9 REAL

Read

Only

Analog Input 9

Usage Notes

Viewing the Analog Voltage
To view the Analog Input values in RMCTools, enter the address of the input in the Map

To column in the Indirect Data Map. The analog input value will appear in the Current

column of the Indirect Data Map.
Uses
These registers can be used for plotting, can be used in expressions, and can be read by

an external device such as a PLC. They can also be used as a gear Master Register, just

like any other REAL register, but notice that no filtering or advanced rate calculations will

be provided. Also, because the input cannot be part of a halt group, the safety of using

the input for gearing must be evaluated by the integrator.
Tag Names
The analog inputs can be referenced with the tag names _AI[i], where i is the input

number. For example analog input 3 is _AI[3].

RMC70 Registers, File 30: Image Area

See the Controller Image Upload/Download topic for details.
Tip:

For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be

read as 'L' type (32-bit word) registers. This is very useful when reading registers with

DWORD or DINT external data types.

AB
DF1,
CSP

Address

Modbus

TCP,RTU

Address

FINS
Address

External
Data Type

Internal
IEC

Address

Internal

Data Type Access

Register

Name

F30:0

15361

D15360 DINT

%MD30.0

DINT

Write Only Image Area

Command

F30:1

15363

D15362 DINT

%MD30.1

DINT

Read Only Image Area

State

F30:2

15365

D15364 DINT

%MD30.2

DINT

Read Only Image Size

F30:3

15367

D15366 DINT

%MD30.3

DINT

Read/Write Current

Index

F30:4
:
F30:4095

15369-
15871
(252

items)

D15368-
D15870
(252

items)

DINT[252]
or
DINT[4092]

%MD30.4
:
%MD30.4095

DINT[252]
or
DINT[4092]

Read/Write Image Data

RMC70 Registers, File 31: Plot Layout

The following files contain the Plot Layout registers.
Tip:

For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be

read as 'L' type (32-bit word) registers. This is very useful when reading data of DWORD or

DINT external data types.

deltamotion.com

1069