beautypg.com

Delta RMC151 User Manual

Page 1064

background image

RMC70/150 and RMCTools User Manual

F13:23 6703

D06702 REAL

%MD13.23 REAL

Actual Pressure/Force Rate

Filter, Actual Jerk Filter

F13:24 6705

D06704 REAL

%MD13.24 REAL

Noise Error Rate

Secondary Feedback: Analog Transducer
F13:28 6713

D06712 DWORD %MD13.28 DWORD Analog Config Register

Analog Control Output
F13:32 6721

D06720 REAL

%MD13.32 REAL

Output Limit

F13:33 6723

D06722 REAL

%MD13.33 REAL

Output Bias

F13:34 6725

D06724 DWORD %MD13.34 DWORD Output Register

Final Output Stage
F13:38 6733

D06732 REAL

%MD13.38 REAL

Output Scale

F13:39 6735

D06734 REAL

%MD13.39 REAL

Primary Output Filter

F13:40 6737

D06736 REAL

%MD13.40 REAL

Secondary Output Filter

F13:41 6739

D06738 REAL

%MD13.41 REAL

Deadband Tolerance

F13:42 6741

D06740 REAL

%MD13.42 REAL

Output Deadband

F13:44 6745

D06744 REAL

%MD13.44 REAL

Knee Command Voltage

F13:45 6747

D06746 REAL

%MD13.45 REAL

Knee Flow Percentage

Primary Control: Servo Position/Velocity Axes
F13:43 6743

D06742 REAL

%MD13.43 DINT

Default Pos/Vel Control Mode

F13:56 6769

D06768 REAL

%MD13.56 REAL

In Position Tolerance

F13:57 6771

D06770 REAL

%MD13.57 REAL

Position Error Tolerance

F13:58 6773

D06772 REAL

%MD13.58 REAL

At Velocity Tolerance

F13:59 6775

D06774 REAL

%MD13.59 REAL

Velocity Error Tolerance

F13:60 6777

D06776 DWORD %MD13.60 DWORD Primary Control Register

Position/Velocity Gain Set #1
F13:61 6779

D06778 REAL

%MD13.61 REAL

Proportional Gain

F13:62 6781

D06780 REAL

%MD13.62 REAL

Integral Gain

F13:63 6783

D06782 REAL

%MD13.63 REAL

Differential Gain

F13:65 6787

D06786 REAL

%MD13.65 REAL

Velocity Feed Forward,
Velocity Feed Forward

(Positive)

F13:66 6789

D06788 REAL

%MD13.66 REAL

Acceleration Feed Forward

F13:67 6791

D06790 REAL

%MD13.67 REAL

Jerk Feed Forward

F13:68 6793

D06792 REAL

%MD13.68 REAL

Velocity Feed Forward

(Negative)

F13:69 6795

D06794 REAL

%MD13.69 REAL

Double Differential Gain,
Active Damping Proportional

Gain

F13:70 6797

D06796 REAL

%MD13.70 REAL

Triple Differential Gain,
Active Damping Differential

Gain

F13:71 6799

D06798 DINT

%MD13.71 DINT

High-Order Control

Position/Velocity Gain Set #2

1044

Delta Computer Systems, Inc.

This manual is related to the following products: