beautypg.com

Bool data type, A bool, Bool – Delta RMC151 User Manual

Page 339

background image

5 Programming

DINT

32-bit integer number.

When typing a DINT number, it must not include a decimal point.

DWORD

32-bit string of bits.
Each bit in a DWORD data type is a boolean and can be individually addressed

by adding "." and then the bit number.

Example: MyDWordVariable.12 is a boolean.
Note:

The DWORD and DINT data types are not interchangeable. A function that

requires a DINT will not accept a DWORD. Use a conversion function to convert

a DWORD to a DINT or a DINT to a REAL.

BOOL

Boolean, 1 bit, either True or False.
For discrete I/O, On = True, Off = False.
As a bit in a DWORD, 1 = True, 0 = False.

Each bit in a DWORD data type is a boolean and can be individually addressed

by adding "." and then the bit number.

Example: MyDWordVariable.12 is a boolean.


To find the data type of a register, use the Address Selection Tool, or the Register Maps.

Arrays

An array is a numerically indexed sequence of elements of the same data type. The RMC

supports arrays of each 32-bit data type: REAL, DINT, and DWORD. See the Arrays topic

for details.

Internal versus External Data Types

Some registers have different data types depending on whether they are accessed from

user programs or externally, such as from a PLC. The RMC150 Register Map and RMC70

Register Map topics list the external and internal data types of the registers. When

reading from and writing to registers in the RMC via one of the communication protocols,

use the external data type.
The different external and internal data types are intended to make it easier to

communicate with the RMC. Some registers that are DINT or DWORD internally are a

REAL externally, so that the PLC does not have to deal with may different data types.

Converting Data Types

When used in expressions, data types can not be mixed without explicitly converting

them. The following functions convert data to different data types:

REAL_TO_DINT(a)

DINT_TO_REAL(a)

DWORD_TO_DINT(a)

DINT_TO_DWORD(a)


See the functions topic for usage details.

5.12.2. BOOL Data Type