9 Register Reference
Only)
3 Read Active
(Read Only)
4 Trigger Enabled
(Read Only)
F34:1
17411
D17410 REAL
%MD34.1 UDINT Read/Write Plot Samples (e.g.
1000)
F34:2
17413
D17412 REAL
%MD34.2 REAL
Read/Write Plot Sample Period
(seconds)
F34:3
17415
D17414 REAL
%MD34.3 DINT
Read/Write Plot Axis Owner
0-3, -1 = none
F34:4
17417
D17416 REAL
%MD34.4 REAL
Read/Write Plot Trigger Position
%, 0-100, -1 =
auto rearm
F34:5
17419
D17418 REAL
%MD34.5 UDINT Read/Write Plot Trigger Type
0-
7
Trigger Type
(0=none,
1=motion
command)
8-
23
Depends on
trigger type
Motion
Commands:
8-
11
Axis 0-3 bits,
if all zero,
then use
Axis Owner
12-
23
Reserved
F34:6
17421
D17420 REAL
%MD34.6
-
-
Reserved
F34:7
17423
D17422 REAL
%MD34.7
-
-
Reserved
F34:8
17425
D17424 REAL
%MD34.8 REAL
Read Only Plot ID
F34:9
17427
D17426 REAL
%MD34.9 REAL
Read Only Plot State
0 = not triggered, 1
= capturing, 2 =
complete
F34:10
17429
D17428 REAL
%MD34.10 DINT
Read Only Plot Captured
Samples
Number of plot
samples captured.
Only applies for Plot
State > 0.
F34:11
17431
D17430 REAL
%MD34.11 DINT
Read Only Plot Sample 0 Time
Time that first plot
sample was
captured. In control
loops since
controller startup