7 Hardware
transducers. Finally, many SSI devices offer higher precision; for example, MDTs with SSI
output are available with resolutions to 2µm.
Note: Linear MDTs with SSI output should be of the synchronized type. Non-synchronized is
not well-suited for motion control.
See the SSI Fundamentals topic for details on the SSI standard.
Features
•
Two axes of SSI feedback per module
•
Supports SSI devices with Binary or Gray Code data from 8 to 31 bits in length
•
Differential RS-422 SSI interface
•
Two isolated, ±10 V, 12-bit control outputs per module
•
Current output up to ±200 mA with VC2124 converter option
Part Number
The part number of the SSI module is Sn, where n is the number of SSI modules.
For example, RMC150E-S1 is an RMC150E with one SSI module. RMC150E-S3-Q1 is an
RMC150E with three SSI modules and one Quadrature module.
Setting Up the SSI Module
To set up axes with SSI feedback, read the following topics:
SSI Wiring
SSI Scaling
The following parameters must be also set for axes with SSI feedback:
•
•
The following advanced parameters can be optionally set for axes with SSI feedback:
•
•
•
•
Specifications
For general specifications on the RMC150, see the RMC150 Overview topic.
SSI Interface
Inputs Two RS-422 differential (does not support single-ended)
Clock Outputs Two RS-422 differential (does not support single-ended)
Clock Frequency user-selectable 230 kHz, 921 kHz
Input Impedance Data + Input: 140 Ω
Data - Input: 150 Ω
Required Cable Type Twisted pair, shielded
Maximum Cable Length Transducer Dependent, approx. 300-600 ft. See the SSI Clock Rate
topic for details.
ESD Protection 15 kV
Resolution Transducer dependent
Count Encoding Binary or Gray Code
deltamotion.com