This bit indicates the move is complete, which occurs when the target has stopped.
Pressure/Force Target Generator State A and B bits
B
A Description
0
0
Reserved
0
1
Reserved
1
0
Reserved
1
1
Reserved
8.5.3.6. Command: Change Target Parameter (Prs/Frc) (81)
Supported Axes: Pressure or Force Axes
Firmware Requirement: 2.30 or newer
Hardware Limitations: RMC75S: versions 2.1D or newer only
RMC75P: versions 2.1E or newer only
RMC75E: No limitations
RMC150E: No limitations
See the Commands Overview topic for basic command information and how to issue
commands from PLCs, HMIs, etc.
Command Parameters
# Parameter Description
Range
1 Parameter
•
Offset (0)
•
Amplitude (1)
•
Frequency (2)
•
Cycles (3)
A valid integer as
described
2 New Value
Depends on
selected
Parameter
3 Ramp Type
•
Time (0)
•
Cycles (1)
•
Rate (2)
•
Time (log) (3)
•
Cycles (log) (4)
A valid integer as
described
4 Ramp Value
Depends on
selected Ramp
Type
Description
This command changes a target parameter for certain types of pressure or force moves
that are in progress. For example, this command can be used to ramp the amplitude of a
814
Delta Computer Systems, Inc.