E rmc70 register map - controller parameters, Controller status/parameters – Delta RMC151 User Manual
Page 1081
9 Register Reference
31
9791
D09790
31
Axis Definitions
The Current Axis Definitions and the Requested Axis Definitions will generally be the same
except in two cases:
(1) The user has written to the requested block and intends to do a warm restart or burn to
flash and do a cold restart, or
(2) The requested axis definitions found on startup are invalid for the current hardware
configuration; in this case the Current Axis Definitions will be the default for the current
hardware configuration.
RMC70 Registers, File 20: Controller Status/Parameters
Address
Modbus
Address
External
Data
Internal
IEC
Address
Internal
Access
Register Name
F20:0
10241
D10240 REAL
%MD20.0 REAL
Read Only Loop Time, Set
F20:1
10243
D10242 REAL
%MD20.1 REAL
none
Loop Time,
Requested
F20:2
10245
D10244 REAL
%MD20.2 REAL
Read Only Loop Time, Length of
Last Used
F20:3
10247
D10246 REAL
%MD20.3 REAL
Read/Write Loop Time, Length of
Maximum Used
F20:4
10249
D10248 REAL
%MD20.4 DINT
Read/Write Number of Tasks
Allocated
0-4 (default = 2)
F20:5
10251
D10250 REAL
%MD20.5 DINT
Read/Write Program Triggers
Task Enabled?
0=false, 1= true
(default = 1)
F20:6
10253
D10252 REAL
%MD20.6 DINT
Read/Write Stop All Tasks on
Any Axis Halt?
0=false, 1= true
(default = 1)
F20:7
10255
D10254 REAL
%MD20.7 DWORD Read Only Controller Status
F20:8
10257
D10256 REAL
%MD20.8 DINT
Read/Write Startup Mode
0=PROGRAM, 1-RUN
(default = 0)
F20:9
10259
D10258 REAL
%MD20.9 DINT
Read/Write RUN/PROGRAM
Input
0=none, 1-
64=%IX(n-1),
256+a=Axis a Fault
Input)
F20:10 10261
D10260 REAL
%MD20.10 REAL
Read Only Time
The _Time register
wraps every second
through the range
[0.000000,
deltamotion.com