beautypg.com

Rmc75p wiring, Aa wiring, Rmc75p wiring 1 – Delta RMC151 User Manual

Page 1151: Aa wiring 1, Rmc75p

background image

10 Wiring and Installation

10.2.4. RMC75P Wiring

The RMC75P CPU module contains a connector for power, and two connectors for

communications.

Wiring Power

The connector screws and wire clamp screws must be tightened to max 7 b-in (0.8Nm).

Wiring the Communications

RS-232 Monitor Port
For wiring the RS-232 Monitor Port, see the RS-232 Wiring for the RMC70 topic.
9-Pin PROFIBUS-DP Connector
This connector is the standard PROFIBUS connector. It is used for connecting the RMC70

to other PROFIBUS-DP devices via a standard PROFIBUS-DP cable. The pin assignment is

defined by the PROFIBUS specification.

10.2.5. AA Wiring

The AA axis module can be wired to voltage or current feedback transducers. The AA module

also a Fault input, Enable output, and a Control Output. If the AA module has two axes, each

axis' pin-out is identical.
Use shielded twisted pairs for all connections to inputs and outputs. Route the transducer

wiring separate from other wiring. You must provide the power supplies needed by your

transducers. See Wiring Guidelines for general wiring information.
Wire clamp screws must be tightened to max 7 b-in (0.8Nm).
NOTE:

The example schematics do not include transducer pin numbers, color codes, or power supply

requirements, since these vary between different transducers. To determine your power

supply needs and connector pin-outs or cable color codes, consult your transducer

manufacturer's documentation.

Pin-Out

Pin

#

AA1 Label

AA2 Label

Function

1

+Fault In

Flt In+

Fault Input

2

-Fault In

Flt In-

3

+Enable Out

En Out+

Enable Output

4

-Enable Out

En Out-

5

Control Out

Ctrl Out

Control Output

deltamotion.com

1131