RMC70/150 and RMCTools User Manual
Address
Modbus
Address
External
Data
Internal
IEC
Address
Internal
Access
Register Name
F31:0
15873
D15872 REAL
%MD31.0 UDINT Read/Write Current Plot Layout
This register indicates
the current plot
allocation.
Bit Description
0-7 Plots (1-8)
8-
15
Sample Sets per
Plot (1-16)
16-
23
Reserved
F31:1
15875
D15874 REAL
%MD31.1 UDINT Read Only Maximum Plots (8)
This read-only value
indicates how many
plots can be defined
at once.
F31:2
15877
D15876 REAL
%MD31.2 UDINT Read Only Maximum Samples
(16)
This read-only value
indicates how many
samples sets can be
captured
simultaneously per
plot.
F31:3
15879
D15878 REAL
%MD31.3 UDINT Read Only Maximum Samples at
Once (128)
This read-only value
indicates how many
total different
samples can be
allocated across all
plots.
F31:4
15881
D15880 REAL
%MD31.4 UDINT Read Only Maximum Elements
RMC75S/P: 32,768
RMC75E: 12,583,912
Note: Prior to 2.00
firmware, the
RMC75E is limited to
32,768 elements.
Prior to 1.02 Loader,
the RMC75E is limited
to 4,194,304.
This read-only value
indicates how many
total data points can
be captured. This is
spread out among the
number of allocated
plots and samples per
1070