beautypg.com

Delta RMC151 User Manual

Page 1090

background image

RMC70/150 and RMCTools User Manual

AB
DF1,
CSP

Address

Modbus

TCP,RTU

Address

FINS
Address

External
Data

Type

Internal
I
EC

Address

Internal

Data

Type

Access

Register Name

F31:0

15873

D15872 REAL

%MD31.0 UDINT Read/Write Current Plot Layout

This register indicates

the current plot

allocation.

Bit Description
0-7 Plots (1-8)
8-

15

Sample Sets per

Plot (1-16)

16-

23

Reserved

F31:1

15875

D15874 REAL

%MD31.1 UDINT Read Only Maximum Plots (8)

This read-only value

indicates how many

plots can be defined

at once.

F31:2

15877

D15876 REAL

%MD31.2 UDINT Read Only Maximum Samples

(16)
This read-only value

indicates how many

samples sets can be

captured

simultaneously per

plot.

F31:3

15879

D15878 REAL

%MD31.3 UDINT Read Only Maximum Samples at

Once (128)
This read-only value

indicates how many

total different

samples can be

allocated across all

plots.

F31:4

15881

D15880 REAL

%MD31.4 UDINT Read Only Maximum Elements

RMC75S/P: 32,768
RMC75E: 12,583,912
Note: Prior to 2.00

firmware, the

RMC75E is limited to

32,768 elements.

Prior to 1.02 Loader,

the RMC75E is limited

to 4,194,304.
This read-only value

indicates how many

total data points can

be captured. This is

spread out among the

number of allocated

plots and samples per

1070

Delta Computer Systems, Inc.

This manual is related to the following products: