Axis parameters pane, Axes parameters pane, E axes parameters pane – Delta RMC151 User Manual
Page 232
RMC70/150 and RMCTools User Manual
4.7.1.3. Axis Parameters Pane
To access this pane:
On the RMCTools toolbar, click the Axis Tools button . If the Axes Parameters pane does
not appear, use the Select Layout box to choose the Axes Parameters pane, or press F6.
To access from the Plot Manager:
Click the Tuning tab (next to the History tab).
The Axis Parameters pane is part of the Axis Tools. It is also part of the Tuning Tools. Use
the Axis Parameters pane for the following:
•
Monitor and edit the Axis Parameters.
•
Set up and tune the RMC.
For general information on using editors, see the Using Editors topic.
Tabs
The Axis Parameters pane has 3 tabs. Within each tab, the registers are arranged in
sections. To expand a section, clicking the '+'.
•
Setup Tab
Use this tab for setting up the controller. This tab contains the basic parameters
required for setup.
•
Tune Tab
Use this tab for tuning the controller. This tab contains the basic parameters required
for tuning.
•
All Tab
Use this tab to edit advanced parameters. This tab contains all the Axis parameters.
Using the Axes Parameter Pane
Editing Parameter Values
•
Find the parameter you wish to edit.
•
Click the cell in the desired Axis column.
•
Type or choose a value and press Enter.
•
Click the Download button to apply the changes to the RMC.
•
To save the values to Flash memory, on the Controller menu, click Update Flash.
Columns
Column
Name
Description
Registers This is the descriptive name of the parameter register, along
with the units.
Reg #
The Reg# column contains the address number for each register.
The addresses apply to the selected axis. To change the address
format, right-click any cell in the Reg # column, choose Address
Formats, and choose the desired format.
Axis
This is the current value for this axis of the register in the Reg #
column. You can edit these values.
Hiding and Showing Columns
212
Delta Computer Systems, Inc.