Delta RMC151 User Manual
Page 1113
9 Register Reference
Holds the patch level of the
firmware version. For example,
for 3.30.0, this value will be 0,
and for 3.30.1, it will be 1.
RMC150 Registers, Files 8-23: Axis Status Registers
All Axis Status Registers are Read Only.
n = axis number (0-15)
f = 8 + n
b = 512 x n
Address
Modbus
Address
External
Data
Internal
IEC
Address
Internal
Register Name
Common Registers: All Axes
Ff:0
4097 + b D4096 +
b
DWORD %MDf.0
DWORD Status Bits
Ff:1
4099 + b D4098 +
b
DWORD %MDf.1
DWORD Error Bits
Ff:2
4101 + b D4100 +
b
REAL
%MDf.2
DINT
Ff:4
4105 + b D4104 +
b
REAL
%MDf.4
REAL
Position/Velocity Control
Ff:6
4109 + b D4108 +
b
REAL
%MDf.6
DINT
Ff:7
4111 + b D4110 +
b
REAL
%MDf.7
DINT
Primary Input: Position/Velocity Axes
Ff:8
4113 + b D4112 +
b
REAL
%MDf.8
REAL
Ff:9
4115 + b D4114 +
b
REAL
%MDf.9
REAL
Ff:10
4117 + b D4116 +
b
REAL
%MDf.10 REAL
Ff:11
4119 + b D4118 +
b
REAL
%MDf.11 REAL
Ff:12
4121 + b D4120 +
b
DINT
%MDf.12 DINT
Primary Input: Single-Input Pressure, Force, or Acceleration Axes
Ff:8
4113 + b D4112 +
b
REAL
%MDf.8
REAL
Ff:9
4115 + b D4114 +
b
REAL
%MDf.9
REAL
Ff:11
4119 + b D4118 +
b
REAL
%MDf.11 REAL
Ff:12
4121 + b D4120 +
b
DINT
%MDf.12 DINT
deltamotion.com
1093